What happens
The CT is on the ground floor and the ward on the third; the porter takes the cylinder on the trolley, which is the one that came back last. The gauge says a third; a third of a D at ten litres a minute is eleven minutes; the lift is held on two. Sprint 10x's oxygen register does the sum for the tank and the manifold; the inter-hospital transfer (Sprint 5x) does it for the road; this does it for the lift.
What the system now does
/ipd/cylinders — IPD → Oxygen cylinders, permission Ipd.Manage: four tiles (out now with those past their expected time, cylinders by state, trips with the mean margin and those sent with under ten minutes to spare, ran out with those that came back empty); the cylinders (tag, size and litres, home, gauge, when read, what that means — minutes at 2, 6 and 10 L/min, or out: … N min so far of M available, or empty — swa…
Where it lives
In-patient (IPD) · /ipd/cylinders